This line of
Drugs of Abuse multi parameters
tests is specifically targeted for
screening new employees as well as for
monitoring drivers and other workers
categories according to each country
regulations.
The tests are CE marked
for professional use as well as suitable
for self control.
They can be performed by
any Doctor or operator on-site, on
urines, in few minutes.
The tests are
competitive sandwich-immuno-assays and
in case there is no drug in the urine
two red lines (test-and control-line)
appear at the strips of the device.
If there is a drug of
abuse in the urine sample only one
control-line appears at the related test
strip.
Here below they are
listed the products specifically
required by latest Italian regulation (
DL 81/08 and subsequent communications
) on safety at work, with their various
formats and particular cut-off.
In case of any need
for a specific combination or in case of
different enquiries as by other country
regulations please freely contact us as
we are able to satisfy any need of DOA
test.
NOTE:
THE LINE IS ONLY AVAILABLE UNDER OEM
BASIS (PRIVATE LABEL) OR OBL
(CO-BRANDING). |
|
MULTI DIP 7 DEVICE
(COC 300), (AMP 500), (MET
500), (THC 50), (OPI 300), (MDMA 500), (MTD
300).
The test system consists on 7
strips for above drugs which are mounted in
a plastics holder.
These test cassettes are
available with three up to twelve strips.
Every side of the device can
locate up to 6 strips so the 7 strips device
has 6 tests at one side and one on the back
side.
To perform the test, the
strip free endings are immerged into the
urine sample for at least 10 seconds.
The
test strips are removed out of the urine
sample when a control line at every single
parameter is visible on the strips.
Protection cup is then placed
again to cover strips endings and the device
is left on a flat surface.
Results are read after min 5
and max 15 minutes.
Accuracy, sensitivity and
specificity of these tests are proven by
available technical sheets to be almost
100%.
The advantage of the multi dip tests is the
maximum flexibility as being strips
independent each other the device can be
assembled with desired tests combination.
|

 |
|
MULTI DIP 8 DEVICE
(BUP
10), (COC 300), (AMP 500), (MET 500),
(THC 50), (OPI 300) (MDMA 500), (MTD 300).
The test system consists on 8
strips for above drugs which are mounted in
a plastics holder.
The procedure is same as
previous combination.
|
|
|
MULTI DIP 8 +
2 ADULTERATION
TESTS DEVICE
(BUP 10 ), (COC 300), (AMP
500), (MET 500), (THC 50), (OPI 300), (MDMA
500), (MTD 300)
+
pH + Creatinine
(BUP 10 ), (COC 300), (AMP
500), (MET 500), (THC 50), (OPI 300), (MDMA
500), (MTD 300)
+ pH + Creatinine
The test system consists on 8
strips for above drugs which are mounted in
a plastics holder + one strip with pH and
Creatinine color pads.
To perform the test, the
strips free endings of the device are
immerged into the urine sample for at least
10 seconds.
|
 |
The
test strips are removed out of the urine
sample when a control line at every single
parameter is visible on the strips.
After 1-2 minutes the color
changing of pH and Creatinine are compared
with
the color chart provided with the
test.
Normal pH-values in urine
vary from pH 4.0 to pH 9.0. Lower or higher
pH-values show an adulteration of the urine
sample.
The DOT guideline states that urine
specimens with Creatinine levels of less
than 20mg/dl
( 50 ng/dl in Italy ) are indicative
of adulteration.
Drug of Abuse test result is read after 5 to
15 minutes from starting time.
|
MULTI DIP 8 + up to 6 ADULTERATION
TESTS DEVICE
(BUP 10 ), (COC 300), (AMP
500), (MET 500), (THC 50), (OPI 300), (MDMA
500), (MTD 300)
ADU tests
available: pH, Creatinine + Nitrites + SG + Glutaraldehyde +
Oxidants
The test system consists on 8
strips for above drugs which are mounted in
a plastics holder + ADU color pads inserted
in the sampling area.
To perform the test, the
strips free endings of the
|

|
To perform the test, the strips
free endings of the device are immerged into the
urine sample for at least 10 seconds.
The
test strips are removed out of the urine sample
when a control line at every single parameter
is visible on the strips.
After 1-2 minutes the ADU tests
colors are compared with
the color chart provided with the test.
Drug of Abuse test result is read after 5 to 15
minutes from starting time.
|
MULTI LINE 7 DEVICE
(COC 300), (AMP 500), (MET
500), (THC 50), (OPI 300), (MDMA 500), (MTD
300).
The test system consists
of 4 strips for 8 drugs which are mounted in
a plastics holder.
Each test strip has a
control zone and one or more drug of abuse
tests zone.
A number of sample wells
corresponding to the strips are located
at one end of the device, corresponding to
the end of each strip. |
 |
Urine is dropped by the operator into each
sample well by using a plastic disposable
pipette, included in the test pouch.
The procedure of the test is then same as for
the multi – dip devices.
The urine will migrate along the strips and will
generate 2 bands C: control and T: test. If one
band of the T zones will not appear, the test is
positive for the DOA correspondent to that band.
The advantage of the multiline tests is that all
test is run at a side of the device so, upon
termination, the result can be photographed or
copied more easily than a double sides
multi-dip.
Due the fact that in the multiline tests each
strip can detect more than one Drug of abuse +
control, the combination in a strip is not
flexible as only DOA which do not interfere each
other can stay on same test strip.
In case of Adulteration tests are needed, the
same are supplied as side strips in tube.
|
MULTI LINE 8 DEVICE
(BUP 10 ), (COC 300), (AMP
500), (MET 500), (THC 50), (OPI 300), (MDMA
500), (MTD 300).
The device is same as above with addition
of buprenorphine
(BUP) test. So 4 strips / 8 tests.
In case of Adulteration tests are needed,
the same are supplied as side strips in
tube. |
 |
|

DOA
COMBO OCCUPATIONAL
A
multidip / multiline test with up to 8
parameters
“ all at one side” of the
device
Avaiable combinations:
1) Multi 7 device :
(COC 300), (AMP 500), (MET
500),
(THC 50), (OPI 300), (MDMA
500), (MTD 300)
2) Multi 7 device +
Adulteration tests (pH and
Creatinine)
3) Multi 8 device
:
(BUP 10 ), (COC 300) , (AMP
500),
(MET
500), (THC 50), (OPI 300), (MDMA 500), (MTD
300)
4) Multi 8 device + Adulteration tests (pH
and
Creatinine)
|
 |
The test system consists on a
plastic holder with several DOA strips + one
strip with pH and creatinine color pads.
The strips are all located in
the FRONT SIDE of the device, so to facilitate
the reading and the photocopy of the test
result.
To allow this, some of the
strips are multiline
strips; it means they detect more than
one DOA contemporarily, so 5 strips can read up
to 8 DOA.
To perform the test, the strips
free endings of the device are immerged into the
urine sample for at least 10 seconds.
The
test strips are removed out of the urine sample
when a control line at every single parameter
is visible on the strips.
After 1- 2 minutes the colors
changing of pH and Creatinine are compared with
color
chart supplied together with the
test.
Normal pH-values in urine vary
from pH 4.0 to pH 9.0. Lower or higher pH-values
show an adulteration of the urine sample.
The DOT guideline states that urine specimens
with Creatinine levels of less than 20mg/dl
(50 mg/dl in Italy) are indicative
of adulteration.
Drug of Abuse test result is read after 5 to 15
minutes from starting time.
|
MULTI 7 CUPS + ADULTERATION
TESTS
Integrated dual chambers
cups with 7 DOA tests, temperature control
and ADU tests.
Graduated urine cups for urine sampling and
testing. The dual chamber allows the urine
to pass from the main cup to the test area
avoiding any contamination of the original
sample.
1.
(COC 300), (AMP 500), (MET 500), (THC
50), (OPI 300), (MDMA 500), (MTD 300)
+ pH and Creatinine.
In the test area there are 7 strips for the
DOA tests as well as 1 strip with
pH and Creatinine
color test pads to identify possible
adulteration of the urine.
2.
COC 300), (AMP 500), (MET 500), (THC 50), (OPI
300), (MDMA 500), (MTD 300)
+ 6 ADU tests.
In the test area there are 7 strips for the
DOA tests, while in sampling area a strip
for up to 6 ADU tests is located to identify
possible adulteration of the urine.
On the cup, the measure of volume, the
patient ID and the temperature control strip
are also located.
The cup is supplied with
security seal
on which it is possible to sign date and
patient name and use it then for sealing the
cup after the test.
|

 |
|
MULTI 8 CUP + ADULTERATION
TESTS DEVICE
Integrated dual chambers
cup with temperature control and ADU tests:
(BUP 10), (COC 300), (AMP 500), (MET 500), (THC
50), (OPI 300), (MDMA 500), (MTD 300)+pH+Creatinine.
The cup is same as above with addition of
buprenorphine
test ( BUP ).
|
|
URINE SAMPLING CUP
with cap ( non sterile )
A plastic urine cup + screw
cap and patient ID.
It can be used for sampling
when device tests are used.
It can be available with or without
temperature control label.

|
 |
|
TEMPERATURE CONTROL LABEL FOR
URINE SAMPLING CUPS |
|
A label to be applied to the
urine cup before sampling in order to check
the temperature.
As usually normal urine cups
have not temperature control, we offer these
labels at side for occupational medicine.
|
 |
|
SCAN READ SYSTEM
We offer easy to use,
flexible reader systems based on a
specific software, a high performing
scanner and bar coded tests.
The system reads most
types of lateral flow immunoassay
membranes, with or without cassettes
(single strips) in a minute, giving
accurate quantitative or qualitative
reading results.
Excellent for screening
and documentation, the system is
composed by CE marked products and is
particularly suitable for Drug of Abuse
multi test screening.
Results are given
immediately and can be stored, printed
by a thermal printer or as A4 patient
report with your letterhead.
|
 |

Bar-Code example |
The unique Bar-Code (
patent pending ) created to be used on
lateral flow single strips or cassettes
provides all information needed to:
-
Automatically identify each assay
and find the correct standard curve
and lot number
-
Automatically time the incubation
for each assay
-
Perform quality control of image and
data
|
Windows and Linux compatible
technology ensure optimal and very competitive
solutions.
All you need to perform an
objective and reliable analysis of qualitative,
semi-quantitative and quantitative assays, is
your PC.
We provide you with
|
1)
a mini scanner extremely quick and
well performing with the software |
 |
|
2)
a USB Key
with the software |
|
3)
DOA
tests cassettes with integrated Bar-Code
and visual ADU reading.
The DOA tests are read
automatically by the instrument while
the ADU color strips are scannered and
included into the report test picture,
so to be printed with the DOA test, but
the color result is read by the Doctor
and manually indicated on the printed
report. |
 |
|
2010
4)
DOA COMBO OCCUPATIONAL
An automated reading of both drugs of
abuse and
adulteration tests with related
integrated report.
The report can be customized.
|
 |
|
How does it work?
It is a very powerful
software platform that can be used to
analyse images.
The software has a
set of common and complex algorithms
which recognise images, and perform
calculations.
And it has a build-in
database for the approved assays and
tests to be read and measured.
A patent pending Bar
Code has been developed to automating
the processes of reading different
devices.
The lateral Flow Reader
can read cassettes with theoretically
any number of strips mounted.
Also there
is no theoretical limitation of the
number of analytes on a single strip /
membrane.
The Lateral Flow Reader
will adapt to any practical number.
One scanner can house
many different cassettes or 3 multi line
tests.
The application will read